dScript series

Ethernet modules

All dScript modules come pre installed with a comprehensive web configuration and control utility, but using the dScript IDE you can develop your own custom firmware, or edit and upload one of the many example projects.

dScript IDE

dScript is is an Editor, Compiler, Programmer and a Multithreaded language for our dScript series of internet connected modules. It compiles to efficient byte codes that are run by the modules on-board runtime.

Although dScript is not BASIC the syntax of dScript will be familiar to anyone who has used Visual Basic or the small Basic chips and modules that are available.

 

8 Items

Set Descending Direction
  1. dS1242

    Network enabled module with fully customizable firmware.

    Relays - 2
    Relay current - Up to 16Amp @24vdc or 250vac 
    Digital I/O - 4 channels, your choice of VFC input or NPN output.
    Analogue Inputs - 2 channels of 10-bit A/D.
    Serial ports - 1 x TTL level serial port.
    Power - 12V DC adaptor, supplied separately
    Configuration & Test interface - HTTP (webpage)
    Control interface - TCP/IP over Ethernet
    Connections - Screw Terminals for N/O N/C and Common contacts
    Ethernet connection - 100mb full duplex

    Learn More
  2. dS378

    Network enabled module with fully customizable firmware.

    Relays - 8
    Relay current - Up to 16Amp @24vdc or 250vac 
    I/O - 7 channels, your choice of VFC input, NPN output, or 10-bit A/D.
    Serial ports - 2 x TTL level serial port. 1x RS485 serial port.
    Power - 12V DC adaptor, supplied separately
    Configuration & Test interface - HTTP (webpage)
    Control interface - TCP/IP over Ethernet
    Connections - Screw Terminals for N/O N/C and Common contacts
    Ethernet connection - 100mb full duplex

    Learn More
  3. dS3484

    Network enabled module with fully customizable firmware.

    Relays - 4
    Relay current - Up to 16Amp @24vdc or 250vac 
    Digital I/O - 8 channels, your choice of VFC input or NPN output.
    Analogue Inputs - 4 channels of 10-bit A/D.
    Serial ports - 2 x TTL level serial port. 1x RS485 serial port.
    Power - 12V DC adaptor, supplied separately
    Configuration & Test interface - HTTP (webpage)
    Control interface - TCP/IP over Ethernet
    Connections - Screw Terminals for N/O N/C and Common contacts
    Ethernet connection - 100mb full duplex

    Learn More
  4. dS2824

    Network enabled module with fully customizable firmware.

    Relays - 24 with optional integrated snubbers.
    Relay current - Up to 16Amp @24vdc or 250vac 
    I/O - 8 channels, your choice of VFC input, NPN output, or 12-bit A/D.
    Serial ports - 1 x TTL level serial port, 1 RS485 port.
    Power - 12V DC adaptor, supplied separately
    Configuration & Test interface - HTTP (webpage)
    Control interface - TCP/IP over Ethernet
    Connections - Screw Terminals for N/O N/C and Common contacts
    Ethernet connection - 100mb full duplex

    Learn More
  5. dS2832

    Network enabled module with fully customizable firmware.

    Relays - 32 with optional integrated snubbers.
    Relay current - Up to 16Amp @24vdc or 250vac 
    I/O - 8 channels, your choice of VFC input, NPN output, or 12-bit A/D.
    Serial ports - 1 x TTL level serial port, 1 RS485 port.
    Power - 12V DC adaptor, supplied separately
    Configuration & Test interface - HTTP (webpage)
    Control interface - TCP/IP over Ethernet
    Connections - Screw Terminals for N/O N/C and Common contacts
    Ethernet connection - 100mb full duplex

    Learn More
  6. dS2242

    Network enabled module with fully customizable firmware.

    Relays - 2
    Relay current - Up to 16Amp @24vdc or 250vac 
    Inputs - 4 that can act as digital, or 10-bit analogue inputs
    Serial ports - 1 x TTL level serial port and 1 RS485 port
    Power - 12V DC adaptor, supplied separately
    Configuration & Test interface - HTTP (webpage)
    Control interface - TCP/IP over Ethernet
    Connections - Screw Terminals for N/O N/C and Common contacts
    Ethernet connection - 100mb full duplex

    Learn More
  7. dS2408

    Network enabled module with fully customizable firmware.

    Relays - 8
    Relay current - Up to 16Amp @24vdc or 250vac 
    OPTO Inputs - 40 optically isolated inputs that are either:

    • 5V to 30v DC. (green PCB)
    • 230 AC (red PCB)

    Serial ports - 1 x TTL level serial port, and 1 RS485 port.
    Power
    - 12V DC adaptor, supplied separately
    Configuration & Test interface - HTTP (webpage)
    Control interface - TCP/IP over Ethernet
    Connections - Screw Terminals for N/O N/C and Common contacts
    Ethernet connection - 100mb full duplex

    Learn More
  8. TCP184

    Network enabled module with fully customizable firmware.

    Relays - 4
    Relay current - Up to 16Amp @24vdc or 250vac 
    I/O - 8 channels, your choice of VFC input, NPN output, or 12-bit A/D.
    Serial ports - 1 x RS485 port.
    Power - AC mains universal input: 90–264V AC, 47-63Hz.
    Configuration & Test interface - HTTP (webpage)
    Control interface - TCP/IP over Ethernet
    Connections - Screw Terminals for N/O N/C and Common contacts
    Ethernet connection - 100mb full duplex

    Learn More